📍 13609 Victory Blvd, Suite 237, Van Nuys CA 91401, USA info@stalwart-inst.com  |  🌍 Worldwide Shipping
HomeProducts ApplicationsAbout Us NewsContact

Autoclave

Model: SGA-110

Autoclave
ModelSGA-110DA/ SGA-110DF/ SGA-110DR
Model DifferenceDA: Standard, DF: Automatic, water feeding+cooling fan, DR: DF+Drying
Capacity(L)110
Dimension (L*W*H, mm)660x644x1180(DA)
Chamber Dimension (Dia*H, mm)ɸ 400x895
Rate Power Supply(w)4600
Stainless Steel Basket (Dia*H, mm)( ɸ 360x250)x2
Power Requirement220V,32A, 50/60Hz
Temperature Accuracy0.1°C
Working Environment5-45°C, relatively humidity 10%-85%
Chamber MaterialSUS 304
Sterilization Temperature105-138°C
Sterilization Time Range1-6000 minutes
Melting Temperature60-100°C
Melting Time Range1-6000 minutes
Warning Temperature45-60°C
Warning Time Range1-9999 minutes
Drying Only for DR model1-3000 minutes drying temperature 80-140°C
Cooling Lock Open Temperature40-80°C for liquid cycle, 40-99°C for other cycles
Sterilization Cycle1.Solid cycle 2.Liquid cycle 3.Liquid with warming cycle 4.Agar cycle 5. Solid with drying(dor(DR) 6. Medical Waste Cycle 7. Customized Cycle
Sterilization Cycle NumberDA can save up to 20 cycles, DF/DR can save up to 60 cycles
Exhaust ModeAutomatic Internal discharging, with a steam collecting bottle inside. Exhaust speed can be selected by 6 levels
Lid Opening wayUp and down
Steam Collector and Water TankDA: embedded 2 steam collector, DF: embedded 2 steam collector and 28L water tank: DR: embedded steam collector and 28L water tank
Preset Range of TimerCan be preset and auto start up to 6 days in advance
Display Range of Pressure gauge-0.1-0.5Mpa
PressureMax Working Pressure:0.27Mpa, Design pressure:0.35Mpa
Controller“Inspiration” fast speed microcomputer controller
Safety Device“eight column evenly distributed” interlocking device, electric double inner locks, lid closing checking, dry scarch protection, over pressure protection, safety value, water level sensor, over temperature protection, temperature monitor, over current and short circuit protection, leakage protection, cooling lock, anti-scald chamber cover and bench, automatic troubles shooting
Autoclaves

Autoclave

Model: SGA-110
To meet the requirement of a future lab SGA Series intelligent autoclaves once-off selection that exempts the worries of continual upgrading.
Key Features
  • Heavy-Gauge Sterilization Chamber The heavy gauge sterilization chamber in a diameter of 40cm offers a massive space to satisfy various sterilization requirements.
    • Microcomputer Control System The latest “Inspiration” fast-speed microcomputer intelligent control system is highly robust. It realizes the total-process controls of sterilization and enables convenient maintenance, inquiry, calibration, recording and upward scalability. It allows three years of administrations to guarantee satisfactory use and management of the autoclave.
    • Water Sterilization Mode Dedicated waste sterilization procedures are established for effective sterilization of lab wastes.
    • Drying Thoroughly drying according to the CE standard, on hot sale in Europe.
    • Cooling Lock Open Temperature Each procedure can set different cooling lock open temperatures according to the thermal inertia of the sterilization object, preventing the user from opening the cover while the sterilization object (particularly liquid) is still in an unsafe state.
    • Simple and Easily Understandable and Operable Control Panel
    • Preset Procedures and Memory Systems Six sterilization procedures and warming procedures are preset for sterilizing, warming and drying of solids and liquids, the melting and warming of agars. There are up to 60 cycles that can be created and saved to be readily used.
    • Safety Mechanical interlocking: the unique “eight-column evenly distributed” interlocking device is safer and more reliable than common interlocking devices. The electric double inner locks enable the control system to monitor the temperature and pressure in the sterilization chamber on a real-time basis and disable opening of the sterilization chamber cover until the safe temperature and pressure are reached, hence guaranteeing the personal safety of the operator.

Interested in Autoclave?

Get pricing, specifications and availability from our instrument specialists.

Request a Quote →
Related Models
More from Autoclaves
Universal Autoclave
Universal Autoclave
SFA-29A
Universal Autoclave
Universal Autoclave
SFA-50
Universal Autoclave
Universal Autoclave
SFA-80
Universal Autoclave
Universal Autoclave
SFA-100
Autoclave
Autoclave
SGA-60
Autoclave
Autoclave
SGA-85

Ready to Equip Your Laboratory?

Our specialists will help you choose the right configuration for your application and budget.

Request a Quote → Browse All Products